- Home
- GOVERNMENT
- Departments
- Building & Safety
Building & Safety
The health and safety of the citizens and City employees is our paramount concern. City services are being modified in order to provide a safe environment while maintaining basic services throughout the pandemic. Your patience and understanding are appreciated.
Permits
The permit window remains closed to the public. For questions, please email permits@beaumontca.gov
Inspections
At this time ALL Building inspections are done virtually via the ZOOM app.
Resources
TYPE OF PERMIT | # OF PLANS NEEDED |
---|---|
Accessory dwelling unit | 5 |
Accessory Structure | 5 |
Addition | 5 |
Deck | 4 |
Demolition | 3 |
Electrical | 3 |
Block Wall | 5 |
Manufactured Home | 5 |
Mechanical | 3 |
Modular Home | 5 |
New Single Family Home | 5 |
New Multi Family Home | 6 |
Patio Cover | 4 |
Plumbing | 3 |
Swimming Pool | 5 |
PV Solar | 3 |
General Repairs | 3 |
Retaining Wall | 5 |
Roof | 3 |
TYPES OF PERMITS | # OF PLANS NEEDED |
---|---|
Accessory Structure | 5 |
Addition | 5 |
Demolition | 4 |
Electrical | 3 |
Block Wall | 5 |
Foundation Only | 5 |
Mechanical | 3 |
New Commerical | 6 |
Plumbing | 3 |
Swimming Pool | 5 |
PV Solar | 4 |
General Repair | 3 |
Roof | 3 |
Shell Building ONLY | 5 |
Exterior Sign | 5 |
Applicable codes for plans filed on or after January 1, 2020
- 2019 California Residential Code (CBC)
- 2019 California Electrical Code (CEC)
- 2019 California Mechanical Code (CMC)
- 2019 California Plumbing Code (CPC)
- 2019 California Energy Code
- 2019 California Historical Building Code (CHBC)
- 2019 California Existing Building Code (CEBC)
- 2019 California Green Building Standards (CALGreen) @(Model.BulletStyle == CivicPlus.Entities.Modules.Layout.Enums.BulletStyle.Decimal ? "ol" : "ul")>
Seismic Design Category (SDC) | D | 2019 CBC |
D2 | 2019 CRC | |
Basic Wind Speed Note: Vult = ultimate design wind speed | Risk Category II Vult = 97 mph | 2019 CBC/ASCE 7-16 |
Vult = 110 mph | 2019 CRC | |
Wind Exposure | C | |
Ambient Temperature | 99OF (for electrical conductors Ampacity corrections factors of 2019 CEC) | |
Soil Bearing Capacity | 1,500 psf (default value per 2019 CBC Table 1806.2) or per soil report. | |
Soil Lateral Bearing Capacity | 100 psf/ft (default value per 2019 CBC Table 1806.2) or per soil report. | |
Climate Zone | 10 | |
Rainfall | 2” per hour, 100-year return or higher values per hydrology report. | |
Snow Load | 5 Lbs. |